Water cooling

As an alternative to fan cooling [+], it is possible to cool the tiles using a water-cooled machine bed.

WARNING

Do not touch tiles without personal protective equipment

Touch hot tiles only with special thermal gloves. Avoid prolonged contact with hot components.

Hot components can cause severe burns to body parts and limbs.

Notice

Avoid heat build-up and waste heat on tiles

Observe the specifications for ambient and operating temperatures and tile loads. Ensure sufficient clearance below the machine bed and sufficient cooling of the tiles. Enclosing the substructure can lead to heat build-up, especially with air cooling.

Insufficient cooling can lead to overtemperature shutdown of the system and damage to components due to heat generation.

Heat sinks can be fitted to dissipate waste heat.

Water cooling 1:
►Fasten the heat sink [1] to the machine bed with four screws [2]
►Observe tightening torques:

Components

Tightening torque [Nm]

Screws, M6

7





►Attach additional heat sinks to each tile