Intended use

1) For further information contact your local Beckhoff branch or support@beckhoff.com.
2) XPlanar tiles are motors with integrated power electronics and generate heat. Heat flow is predominantly from the top to the bottom of the tile. The more demanding the application, the more heat is generated. For trouble-free operation, appropriate heat dissipation must be ensured on the underside of the tile. For more demanding applications, it may be necessary to implement forced convection by fans or water cooling to prevent overheating.

Specifications for intended use

Insulation material class

F according to IEC 60085; UL1446 class F

Protection rating

1)

Cooling

Convection

Optional: Forced cooling via fan or water cooling2)

Installation position

Horizontal, stator surface upwards

Vibration resistance, horizontal, stator facing upwards

Conforms to EN 60068-2-6

Shock resistance

Conforms to EN 60068-2-27

EMC requirements

Conforms to EN61000-6-2 / EN61000-6-4

EMC category

Category C3 - standard

Category C2, C1 - auxiliary filter required

Approvals

CE

cURus

In preparation: EAC

Overvoltage category

III according to IEC 60664-1