Power cable

Power is supplied to the tiles via star distributors or T-connectors. The star distributors are available in the following versions:

Power cable 1:

ZC2000-0000-0017

The star distributor supplies power to up to six APS4322-0000 tiles.

Coupling: 6 x M12 straight, K-coded

Cable length: 5 m supply cable with open end

Tile layout: 2 x 3

Power cable 2:

ZC2000-0000-0018

The star distributor supplies power to up to four APS4322-0000 tiles.

Coupling: 4 x M12 straight, K-coded

Cable length: 5 m supply cable with open end

Tile layout: 2 x 2

Power cable 3:

ZC2000-0000-0020

The star distributor supplies power to up to six APS4322-0000 tiles.

Coupling: 6 x M12 angled, K-coded

Cable length: 5 m supply cable with open end

Tile layout: 2 x 3

Power cable 4:

ZC2000-0000-0021

The star distributor supplies power to up to four APS4322-0000 tiles.

Coupling: 4 x M12 angled, K-coded

Cable length: 5 m supply cable with open end

Tile layout: 2 x 2

Power cable 5:

ZC2000-0000-0034

The star distributor supplies power to up to six APS4322-0000 tiles.

Coupling: 6 x M12 straight, K-coded

Cable length: 5 m supply cable with open end

Tile layout: 1 x 6

Power cable 6:

ZC2000-0000-0035

The star distributor supplies power to up to six APS4322-0000 tiles.

Coupling: 6 x M12 angled, K-coded

Cable length: 5 m supply cable with open end

Tile layout: 1 x 6

Power cable 7:

ZK1096‑8181-0xxx

The Industrial Ethernet/EtherCAT G/G10 cable for fixed installation is available in different lengths.

Connector: M12 straight to M12 straight, X-coded


0xxx - cable length

0004 – 0.4 m

…

0850 – 85.0 m

Power cable 8:

ZK1096‑8181-4xxx

The drag-chain suitable Industrial Ethernet/EtherCAT G/G10 cable is available in different lengths.

Connector: M12 straight to M12 straight, X-coded

Bending cycles: 4 million


4xxx - cable length

4010 – 0.4 m

4030 – 3.0 m

4050 – 5.0 m

Power cable 9:

ZK1096-8191-0xxx

The Industrial Ethernet/EtherCAT G/G10 cable for fixed installation is available in different lengths.

Connector: RJ45 to M12 straight, X-coded


0xxx - cable length

0020 – 2.0 m

…

0500 – 50.0 m

Power cable 10:

ZK1096‑8191-4xxx

The drag-chain suitable Industrial Ethernet/EtherCAT G/G10 cable is available in different lengths.

Connector: RJ45 to M12 straight, X-coded

Bending cycles: 4 million


4xxx - cable length

4030 – 3.0 m

4050 – 5.0 m

4060 – 6.0 m

Power cable 11:

ZK1096-819A-0xxx

The Industrial Ethernet/EtherCAT G/G10 cable for fixed installation is available in different lengths.

Connector: ix Industrial™ Type A to M12 straight, X-coded


0xxx - cable length

0075 – 7.5 m

0100 – 10.0 m

0150 – 15.0 m

0200 – 20.0 m

0300 – 30.0 m

Power cable 12:

ZK1096‑8383-0xxx

The Industrial Ethernet/EtherCAT G/G10 cable for fixed installation is available in different lengths.

Connector: M12 angled to M12 angled, X-coded


0xxx - cable length

0003 – 0.35 m

0005 – 0.5 m

0006 – 0.6 m

Power cable 13:

ZK1096‑8391-0xxx

The Industrial Ethernet/EtherCAT G/G10 cable for fixed installation is available in different lengths.

Connector: RJ45 to M12 angled, X-coded


0xxx - cable length

0015 – 2.0 m

0030 – 3.0 m

0050 – 5.0 m

0075 – 7.5 m

0100 – 10.0 m