Tile orientation

Notice

Insert the tile correctly

All tiles must have the same orientation in order to be able to control the movers. The point of origin is the same for each tile. Insert the tile according to the following description.

An incorrectly installed tile leads to problems with the mover control via the software.

Tile orientation 1:

Item number

Name

1

Sticker with coordinate origin

Make sure that all tiles have the same orientation. Use the coordinate origin [1] as a guide to align tiles correctly.

Tile orientation 2:
Position another tile [1] with the hole and the elongated hole on the locating pins [2]
Note the tile orientation
Tile orientation 3:
Fasten the additional tile [1] with two, four or six screws [2]
Observe tightening torques

Component

Tightening torque [Nm]

M6 screws

7






Mount other tiles in the same way