Mounting
Make sure that you align the ID bumper correctly. The labels on the mover and on the ID bumper must have the same orientation. Incorrectly aligned ID bumpers can cause problems when controlling the movers.
- ►Insert aligned ID bumper [1]
- ►Fasten ID bumper [1] with screws [2]
- ►Observe tightening torques:
| Component | Tightening torque [Nm] | 
|---|---|
| Screw M3 x 6 | 1.5 | 
- ►Remove the mover [1] from the transport securing device [2] and rotate it by 180°
- ►Place the mover [1] in the transport securing device [2] with the upper side facing upwards
OR
- ►Place the mover [1] straight on the stator surface [3] with the upper side facing upwards
- ►Make sure that the mover is correctly aligned
- ►Make sure that your fingers are not underneath the mover [1] and that the mover is at a sufficient distance from other movers