Disassembly

Disassembly 1:
►Remove the mover [1] from the transport securing device [2] and rotate it by 180°

OR

►Remove the mover [1] from the stator surface [3] and rotate it by 180°
Disassembly 2:

Note the orientation

Before placing the mover in the transport securing device, note the orientation of the mover. For correct mounting of the ID bumper, the ID bumper and the mover must have the same orientation.

Disassembly 3:
►Place the mover [1] in the transport securing device [2] with the underside facing upwards

Notice

Permanent magnets can attract tools

The permanent magnets on the underside of the movers are now exposed and can attract tools used to remove the bumpers.

Disassembly 4:

Different bumper design possible

Depending on the production date of your mover, the bumper may consist of one or four parts. However, the number of screws and fastening points are identical.

Bumper 1-piece

Disassembly 5:
►Remove screws [1]
►Remove a bumper [2]

Bumper 4-piece

Disassembly 6:
►Remove screws [1]
►Remove a bumper [2]
►Remove other bumpers in the same way