Packaging
The packaging contains the following handling instructions:
ESD protection component
The packaging contains electrostatically sensitive components.
Prohibited for people with pacemakers
The packaging contains components with magnetic fields. There is a risk for:
- People with cardiac pacemakers
- People with magnetically conducting implants
- People with internal and external defibrillators
A safety distance of 250 mm from all magnetic parts applies.
No direct contact with magnetic components in the vicinity of parts susceptible to interference is permitted.
Magnetic field warning
The packaging contains components with magnetic fields. There is a risk for:
- Magnetic data storage devices
- Chip cards with magnetic strips
- Electronic devices
A limit range of < 0.5 mT is achieved at a distance of 150 mm in the switched-on state and at a distance of 130 mm in the switched-off state. The magnetic field poses a hazard to people and the environment.
The regulations for magnetic fields in air transportation apply (IATA Packing Instruction 953).