Mechanical protection
Non-magnetic material can be used for the mechanical protection.
The mechanical protection [1] must protrude at least 16 mm beyond the stator surface [2].
APS | 4224-1x00 | APS4242-1x00 | APS4244-1x00 |
|---|---|---|---|
Width [A] | 160 | 320 | 320 |
Height [B] | 320 | 160 | 320 |
The mechanical protection [1] must cover the entire width [A] and height [B] of the tile [2].
Each tile has a total of eight threaded holes for fastening the mechanical protection, two on each outer side of the tile. Further information can be found in chapter Screws for installing the mechanical protection.