Mover alignment

Mover alignment 1:

Position

Name

1

XY axes of the mover

2

Sticker with coordinate origin

When placing the movers, make sure that the XY axes of the mover [1] correspond to the XY axes of the tile. The coordinate origin of the tile is used for orientation. Further information can be found in chapter Tile orientation.

Mover alignment 2:

When placing the movers [1], ensure that they are positioned as parallel as possible to the outer edges of the tile [2].

WARNING

Only grip the mover from the side

When placing a mover on the tiles, only grip the mover from the side.

Magnetic attraction both between the mover and the tile and between two movers can result in serious injury to fingers from crushing and to eyes from splinters.

Notice

Check the underside of the mover for adhesions

Check the underside of the mover for adhesions and clean if necessary.

Adhesive deposits can cause damage to the tile surface.

Notice

Check the tile surface

Check that the tile surface is free of damage and foreign bodies.

Foreign bodies can cause damage to the tile surface. Replace any damaged tiles.

Mover alignment 3:
►Take the mover [1] out of the transport securing device [2] with a straight upward movement
►Position the mover [1] straight in the center of the adjacent tile [3]
►Make sure that your fingers are not underneath the mover and that the mover is at a sufficient distance from other movers
Mover alignment 4:
►Remove the transport securing device [1]
►Position the remaining movers on the tiles in the same way