Placing the mover

WARNING

Do not place the mover until the system test has been completed

The movers may only be placed once the mechanical installation - part 1, electrical installation and system test have been completed.

Failure to do so may result in serious injury to fingers from crushing or to eyes from splinters.

WARNING

Wear safety goggles and gloves

The movers can have strong magnetic attraction to each other or other metallic objects. Splinters can form if magnets collide.

Failure to do so may result in serious injury to fingers from crushing or to eyes from splinters.

WARNING

Remove each mover individually from the box

If you take two movers out of the box at the same time and the distance between the movers is too small, the movers may attract each other.

If the movers attract each other and collide, serious injuries to the fingers from crushing and in the eyes from splinters can result.

WARNING

Do not reach under the mover with your fingers

When carrying a mover or placing it on the system, do not reach under the mover with your fingers. Only grab the mover by the side of the bumper and carry it.

Failure to do so can result in severe crushing and injury to fingers.

WARNING

Movers contain strong permanent magnets

The permanent magnets are arranged in so-called Halbach arrays, which ensure that the magnetic field on the underside of the mover is significantly stronger than on the upper side of the mover. The field of the permanent magnets is present even when the power supply is switched off.

If the movers attract each other and collide, serious injuries to the fingers from crushing and in the eyes from splinters can result.