Installing the heat sink

WARNING

Do not touch tiles without personal protective equipment

Touch hot tiles only with special thermal gloves. Avoid prolonged contact with hot components.

Hot components can cause severe burns to body parts and limbs.

Notice

Avoid heat build-up and waste heat on tiles

Observe the specifications for ambient and operating temperatures and tile loads. Ensure sufficient clearance below the machine bed and sufficient cooling of the tiles. Enclosing the substructure can lead to heat build-up, especially with air cooling.

Insufficient cooling can lead to overtemperature shutdown of the system and damage to components due to heat generation.

Heat sinks can be fitted to dissipate waste heat.

Installing the heat sink 1:
►Fasten the heat sinks [1] on one side of the cover to the machine bed with two screws [2]
►Observe tightening torques:

Components

Tightening torque [Nm]

M6 screws

7

Installing the heat sink 2:
►Fasten the additional heat sink [1] on the opposite side of the cover to the machine bed using two screws [2]
►Observe tightening torques:

Components

Tightening torque [Nm]

M6 screws

7





►Attach additional heat sinks on both sides of each tile