Disassembly
- ►Remove the mover [1] from the transport securing device [2] and rotate it by 180°
OR
- ►Remove the mover [1] from the stator surface [3] and rotate it by 180°
![]() | Note the orientation Before placing the mover in the transport securing device, note the orientation of the mover. For correct mounting of the ID bumper, the ID bumper and the mover must have the same orientation. |
- ►Place the mover [1] in the transport securing device [2] with the underside facing upwards
Notice | |
Permanent magnets can attract tools The permanent magnets on the underside of the movers are now exposed and can attract tools used to remove the bumpers. |
![]() | Different bumper design possible Depending on the production date of your mover, the bumper may consist of one or four parts. However, the number of screws and mounting points are identical. |
Bumper 1-piece
- ►Remove screws [1]
- ►Remove a bumper [2]
Bumper 4-piece
- ►Remove screws [1]
- ►Remove a bumper [2]
- ►Remove other bumpers in the same way
