Credentials
![]() | Changing the standard password For security reasons, change the standard password after logging in for the first time. |
When TwinCAT/BSD is delivered, a user (Administrator) is available by default, with which you can log on to the console. This user does not have conventional administrator rights like under Windows systems but has the authority to obtain root rights for certain purposes. Use the doas command to obtain root rights. doas corresponds to the command sudo, a command known from other Unix-like operating systems.
Login data:
- Login:
Administrator - Password:
1
Proceed as follows:
- 1. Start the Industrial PC.
- 2. Log in with the user name
Administratorand the password1. - 3. After successful login, the user and the host name of the Industrial PC is displayed. For example: CX-1D7BD4.
Administrator@CX-1D7BD4$- 4. Enter the command
passwdin order to set a new password for TwinCAT/BSD. Follow the instructions.
- You have successfully logged in and set a new password for TwinCAT/BSD.