CreateDefaultParams()

CreateDefaultParams() 1:

Creates a default parameterization for all temperature zones.

Syntax:

METHOD CreateDefaultParams : HRESULT
VAR_INPUT
    bAllInUse:              BOOL;                    
    eSensor:                E_TcPfw_TempSensType;    
    eTerminal:              E_TcPfw_TerminalType;
    nChPerTerm:             INT;            
    eOutHeating:            E_TcPfw_TctrlOutSelect;
    eOutCooling:            E_TcPfw_TctrlOutSelect;
    fSetpoint:              LREAL;                    
    fStandbySetp:           LREAL;                    
    fPwmCycleTime:          LREAL;                    
END_VAR

CreateDefaultParams() 2: Inputs

Name

Type

Description

Recommended standard

bAllInUse

BOOL

All zones are initialized as "InUse".

TRUE

eSensor

E_TcPfw_TempSensType

Sensor type - NoSensor in simulation mode

eTcPfwTempSensT_NoSensor

eTerminal

E_TcPfwTerminalType

Terminal type - NoTerminal in simulation mode

eTcPfwTermT_NoTerminal

nChPerTerm

INT

Number of channels per terminal

8

eOutHeating

E_TcPfw_TctrlOutSelect

Output type of the heating output - NoSignal, to disable the heating function (e.g. for measuring zones)

eTcPfwTcOut_PWM

eOutCooling

E_TcPfw_TctrlOutSelect

Cooling output type

eTcPfwTcOut_NoSignal

fSetpoint

LREAL

Temperature setpoint for all zones

180.0

fStandbySetp

LREAL

Temperature setpoint for standby temperature of all zones

18.0

fPwmCycleTime

LREAL

PWM cycle time for all outputs (dutyCycle = fPwmCycleTime * 0.1)

1.0

CreateDefaultParams() 3: Outputs

Name

Type

Description

CreateDefaultParams

HRESULT

Return value with feedback on the success of the execution

Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT v3.1.4024.35

PC or CX (x64, x86)

Tc3_PlasticBaseApplication (>= v3.12.5.0)