Injection pressure simulation

Injection pressure simulation 1:

This class implements a rudimentary simulation of the melt pressure of an injection process. For this purpose, a pressure sensor is simulated, which is synchronized into the controller via an analog interface (preferably FB_InputAnalog16).

Internally, a distinction is made in the class between the metering phase and the injection phase. For this purpose, both the rotary drive of the metering screw and the linear thrust drive must be provided in the simulation by an FB_SimAxCommon-based axis.

Syntax:

FUNCTION_BLOCK FB_SimInjectionMeltPressure

Injection pressure simulation 2: I/O variables

Name

Type

Direction

Description

AnalogValue

INT

Output

The simulated pressure as an analog value.

EC.WcState

BOOL

Output

The simulated Working Counter State.

EC.Toggle

BOOL

Output

The simulated toggle bit.

EC.InfoDataState

UINT

Output

The simulated Device State.

EC.AdsAddr

AMSADDR

Output

The simulated ADS address.

Injection pressure simulation 3: Properties

Name

Type

Access

Description

AutoAdjustMeteringFactor

BOOL

Get, Set

If TRUE, the MeteringFactor is adjusted to the difference between the metered plastic and the linear thrust axis position after the metering process. This option is used to quickly calibrate the metering factor when activated for a short time.

If activated permanently, this option tends to incrementally reduce the MeteringFactor.

Cavity

LREAL

Get, Set

Simulated cavity in length units of the linear thrust axis (typ. [mm]).

CycleTime

LREAL

Get, Set

Cycle time with which the simulation is called.

Enable

BOOL

Get, Set

If not TRUE, the sensor does not respond to any movements of the linked axes.

InjectionResistance

LREAL

Get, Set

Resistance in pressure units (typ. [bar]) during injection, for example, through an upstream injection nozzle.

Injector

I_SimAxCommon

Get, Set

Interface to the linear thrust axis.

The assignment of a simulated axis is mandatory.

IsInjecting

BOOL

Get

TRUE if the simulation has detected an injection process and is actively simulating it.

IsMetering

BOOL

Get

TRUE if the simulation has detected a metering process and is actively simulating it.

Metering

I_SimAxCommon

Get, Set

Interface to the rotary metering screw.

The assignment of a simulated axis is mandatory.

MeteringFactor

LREAL

Get, Set

Specifies the increase in metered plastic during the metering process. The value is measured in length units of the linear thrust axis per revolution of the rotary metering screw (typ. [mm/360°]).

Pressure

LREAL

Get

Current simulated pressure value.

PressureFactor

LREAL

Get, Set

Melt pressure generated per length unit of the linear thrust axis (typ. [bar/mm]). This value represents the compressibility of the liquid injection mass.

ShrinkingFactor

LREAL

Get, Set

The larger this factor is, the faster the plastic shrinks during simulated cooling. Cooling begins as soon as the filling volume of the cavity is reached.

WipeAfterMetering

BOOL

Get, Set

If TRUE, the metered volume is synchronized to the current position of the linear thrust axis after the metering process has been completed.

This option improves the stability of the simulation process. This prevents overpressure arising from incorrectly set back pressure control from influencing the start of the injection process.

Injection pressure simulation 4: Methods

Name

Description

Cyclic()

Cycle method

Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT v3.1.4024.71

PC or CX (x64, x86)

Tc3_PlasticFunctions (>= v12.12.0.0)