ActuatorParamsH

ActuatorParamsH 1:

Exclusive function for actuators

This core function is only available for actuators.

ActuatorParamsH 2:

This core function combines several parameters per end position of an actuator.

The core function is a member of the group of permanently active core functions.

Syntax:

FUNCTION_BLOCK FB_ParamActuatorH EXTENDS FB_Corefunction

ActuatorParamsH 3: Properties

Name

Type

Access

Description

FeedbackDelay

LREAL

Get, Set

Delay [s] of the feedback signal.

FeedbackDelayOff

LREAL

Get, Set

Delay [s] of the falling edge of the feedback signal.

HoldOutput

BOOL

Get, Set

When the motion commands are canceled, the output should remain active.
The output remains pending only if the end position has been reached.

InvertFeedback

BOOL

Get, Set

The interpretation of the feedback signal is inverted (InPos = FALSE).

LatchFeedback

BOOL

Get, Set

The feedback signal is saved after the end position has been reached.

ReturnEarly

BOOL

Get, Set

Allows the time-based reset command to be triggered without the end position having been reached.

ReturnTime

LREAL

Get, Set

Time [s] after which the actuator automatically commands itself back in the opposite direction.

ReturnTimeEna

BOOL

Get, Set

Enables the time-based reset command.

Timeout

LREAL

Get, Set

Time [s] after the end position must be reached. Otherwise, the actuator goes into the error state.

UseImpulse

BOOL

Get, Set

The output is canceled when the end position is reached.

ActuatorParamsH 4: Interfaces

Type

Description

I_ActuatorParamsH

Standard interface on FB_ActuatorParamsH.

Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT v3.1.4024.71

PC or CX (x64, x86)

Tc3_PlasticFunctions (>= v12.12.0.0)