SetParameter()

SetParameter() 1:

A set of parameters specific to this homing procedure is set.

Syntax:

METHOD SetParameter : HRESULT
VAR_INPUT
    eSwitchMode                     : E_AdaptableSwitchMode;
    bOptionsDisableDriveAccess      : BOOL;
    bOptionsEnableLagErrorDetection : BOOL;
END_VAR

SetParameter() 2: Return value

Name

Type

Description

SetParameter

HRESULT

Return value with feedback on the success of the execution.

SetParameter() 3: Inputs

Name

Description

eSwitchMode

Defines how the AbsoluteSwitch is interpreted as a homing event.

bOptionsDisableDriveAccess

A TRUE prevents the underlying motion technology from using ADS communication via the fieldbus to change parameters of the controlled device and return to normal operation.

This option must be used for most non-Beckhoff servo drives.

bOptionsEnableLagErrorDetection

A TRUE will enable the following error monitoring while the function is being executed.

Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT v3.1.4024.35

PC or CX (x64, x86)

Tc3_PlasticFunctions v3.12.4.26 or higher