SetParameter()

The procedure for returning to normal operation can be specified.
Syntax:
METHOD SetParameter : HRESULT
VAR_INPUT
bOptionsDisableDriveAccess : BOOL;
END_VAR
Return value
Name | Type | Description |
|---|---|---|
SetParameter | HRESULT | Return value with feedback on the success of the execution. |
Inputs
Name | Type | Description |
|---|---|---|
bOptionsDisableDriveAccess | BOOL | A TRUE prevents ADS communication via the fieldbus from being used to change parameters of the controlled device in order to return to normal operation. |
![]() | Non-Beckhoff servo drives This option must be used for most non-Beckhoff servo drives. |
Requirements
Development environment | Target platform | PLC libraries to include |
|---|---|---|
TwinCAT v3.1.4024.35 | PC or CX (x64, x86) | Tc3_PlasticFunctions v3.12.4.26 or higher |