SetParameter()

SetParameter() 1:

This method can be used to set the parameters for identification.

Syntax:

METHOD SetParameter : HRESULT
VAR_INPUT
    EnableArreaRatio           : BOOL;
    EnableEndOfTravel          : BOOL;
    EnableOverlapp             : BOOL;
    EnableValveCharacteristic  : BOOL;
    EnableZeroAdjust           : BOOL;
    EndOfTravelNegativ         : LREAL;
    EndOfTravelPositiv         : LREAL;
    EndOfTravelNegativLimit    : LREAL;
    EndOfTravelPositivLimit    : LREAL;
    EndOfVelocityNegativLimit  : LREAL;
    EndOfVelocityPositivLimit  : LREAL;
    DecelerationFactor         : LREAL;
    ValveCharacteristicLowEnd  : LREAL;
    ValveCharacteristicHighEnd : LREAL;
    ValveCharacteristicRamp    : LREAL;
    ValveCharacteristicSettling: LREAL;
    ValveCharacteristicRecovery: LREAL;
    ValveCharacteristicMinCycle: LREAL;
    ValveCharacteristicTblCount: INT;
    ValveCharacteristicType    : INT;
    ValveLinLimitM             : LREAL;
    ValveLinLimitP             : LREAL;
END_VAR

SetParameter() 2: Return value

Name

Type

Description

SetParameter

HRESULT

See below

The return value of the method is of type HRESULT. The following return values are to be expected.

E_AdsErr

Return value

Cause

DEVICE_BUSY

0x9B00 0708

The axis is busy performing another core function.

DEVICE_INVALIDDATA

0x9B00 0706

Not all data and parameters for the core function are available and valid.

DEVICE_INVALIDSTATE

0x9B00 0712

The state of the axis does not allow the execution.

DEVICE_NOTINIT

0x9B00 0718

The core function is not or not completely initialized.

NOERR

0x1B00 0000

The core function has accepted the command.

SetParameter() 3: Inputs

Name

Type

Description

EnableArreaRatio

BOOL

A TRUE will request a separate identification of effects caused by cylinder asymmetry.

EnableEndOfTravel

BOOL

A TRUE will request a separate identification of mechanical travel limits.

EnableOverlapp

BOOL

A TRUE will request a separate identification of effects caused by valve overlap.

EnableValveCharacteristic

BOOL

A TRUE will request the identification of the valve transfer characteristics.

EnableZeroAdjust

BOOL

A TRUE will request a separate identification of effects caused by valve offset.

EndOfTravelNegativ

LREAL

A mechanical travel limit. This value may be found by identification or entered by using an HMI.

EndOfTravelPositiv

LREAL

A mechanical travel limit. This value may be found by identification or entered by using an HMI.

EndOfTravelNegativLimit

LREAL

This value defines a control value limit. The identification will be concluded for that direction if the output to the control device has reached the limit.

EndOfTravelPositivLimit

LREAL

This value defines a control value limit. The identification will be concluded for that direction if the output to the control device has reached the limit.

EndOfVelocityNegativLimit

LREAL

This value defines an actual velocity limit. The identification will be concluded for that direction if the actual velocity exceeds the limit.

EndOfVelocityPositivLimit

LREAL

This value defines an actual velocity limit. The identification will be concluded for that direction if the actual velocity exceeds the limit.

DecelerationFactor

LREAL

This value defines the limits of travel that will be used for the identification.

ValveCharacteristicLowEnd

LREAL

This value defines the limits of travel that will be used for the identification.

ValveCharacteristicHighEnd

LREAL

This value defines the limits of travel that will be used for the identification.

ValveCharacteristicRamp

LREAL

This parameter defines the ramping to the output value currently under investigation.

ValveCharacteristicSettling

LREAL

This parameter defines the delay for starting the investigation after ramping to the output value.

ValveCharacteristicRecovery

LREAL

This parameter defines a recovery time before continuing the identification in the opposite direction.

ValveCharacteristicMinCycle

LREAL

This value specifies a minimum limit for identification.

ValveCharacteristicTblCount

INT

This parameter defines the number of points in the linearization table.

This value must be an odd number. It must be in the range of 5 to 1001. Recommended values are 101, 201 or 401.

ValveCharacteristicType

INT

This parameter is reserved to indicate the use of valves with special behavior details.

For more details, see the hydraulics library documentation.

ValveLinLimitM

LREAL

This value limits the use of the linearization table.

ValveLinLimitP

LREAL

This value limits the use of the linearization table.

Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT v3.1.4024.35

PC or CX (x64, x86)

Tc3_PlasticFunctions v3.12.4.26 or higher

Tc3_PlasticHydraulic v3.12.4.26 or higher