Monitoring

NuGet package: Beckhoff.TwinCAT.HMI.Plastic.Controls

Available: since version 12.8.0

Monitoring control is used to visualize and configure multiple FB_Monitoring objects in the PLC from a single framework control.

The image shows how seven different instances of FB_Monitoring are visualized on this control.

Monitoring 1:

Every individual monitoring object will be represented with its own element.

Monitoring 2:

Components of every monitoring element:

  1. Header text or label
  2. A linear gauge showing the actual value against colored ranges that highlight different limits.
  3. Descriptor text for each input field.
  4. Input controls allowing user to enter Limit Low Low, Limit Low, Limit High and Limit High High settings.
  5. Value being monitored in digits.

Available: since version 12.8.0