UpdateParametersSettingsControls
function UpdateParametersSettingsControls(): voidThe function UpdateParametersSettingsControls assigns different symbols to the following controls depending on the TargetContent property of the TcHmiRegion control with the ID Portrait_MainContent_Region.
Control ID | Control type | Property |
|---|---|---|
Parameters_Settings_Load_Button | TcHmi.Controls.Beckhoff.TcHmiButton | StateSymbol |
Parameters_Settings_Save_Button | TcHmi.Controls.Beckhoff.TcHmiButton | StateSymbol |
Parameters_Settings_CreationDateValue_Textblock | TcHmi.Controls.Beckhoff.TcHmiTextblock | Text |
Parameters_Settings_StoreCountValue_Textblock | TcHmi.Controls.Beckhoff.TcHmiTextblock | Text |
Parameters_Settings_StoredDateValue_Textblock | TcHmi.Controls.Beckhoff.TcHmiTextblock | Text |
Parameters_Settings_Load_StateIndicator | TcHmi.Controls.Plastic.StateIndicator | IndicatorStatus |
Parameters_Settings_Save_StateIndicator | TcHmi.Controls.Plastic.StateIndicator | IndicatorStatus |
Contents/Navigation/Parameters/Parameters_Temperature.content
Control ID | PLC Symbol |
|---|---|
Parameters_Settings_Load_Button | PLC1.Temperature.fbTempCtrlHmi::fbParamHandle::Load |
Parameters_Settings_Save_Button | PLC1.Temperature.fbTempCtrlHmi::fbParamHandle::Save |
Parameters_Settings_CreationDateValue_Textblock | PLC1.Temperature.fbTempCtrlHmi::fbParamHandle::FileCreationDate |
Parameters_Settings_StoreCountValue_Textblock | PLC1.Temperature.fbTempCtrlHmi::fbParamHandle::FileStoreCount |
Parameters_Settings_StoredDateValue_Textblock | PLC1.Temperature.fbTempCtrlHmi::fbParamHandle::FileStoreDate |
Parameters_Settings_Load_StateIndicator | PLC1.Temperature.fbTempCtrlHmi::fbParamHandle::LoadingStatus |
Parameters_Settings_Save_StateIndicator | PLC1.Temperature.fbTempCtrlHmi::fbParamHandle::SavingStatus |
Contents/Navigation/Parameters/Parameters_MainExtruder.content
Control ID | PLC Symbol |
|---|---|
Parameters_Settings_Load_Button | PLC1.Extruder.fbMainExtruderHmi::fbParamHandle::Load |
Parameters_Settings_Save_Button | PLC1.Extruder.fbMainExtruderHmi::fbParamHandle::Save |
Parameters_Settings_CreationDateValue_Textblock | PLC1.Extruder.fbMainExtruderHmi::fbParamHandle::FileCreationDate |
Parameters_Settings_StoreCountValue_Textblock | PLC1.Extruder.fbMainExtruderHmi::fbParamHandle::FileStoreCount |
Parameters_Settings_StoredDateValue_Textblock | PLC1.Extruder.fbMainExtruderHmi::fbParamHandle::FileStoreDate |
Parameters_Settings_Load_StateIndicator | PLC1.Extruder.fbMainExtruderHmi::fbParamHandle::LoadingStatus |
Parameters_Settings_Save_StateIndicator | PLC1.Extruder.fbMainExtruderHmi::fbParamHandle::SavingStatus |
Contents/Navigation/Parameters/Parameters_CoExtruder.content
Control ID | PLC Symbol |
|---|---|
Parameters_Settings_Load_Button | PLC1.Extruder.fbCoExtruderHmi::fbParamHandle::Load |
Parameters_Settings_Save_Button | PLC1.Extruder.fbCoExtruderHmi::fbParamHandle::Save |
Parameters_Settings_CreationDateValue_Textblock | PLC1.Extruder.fbCoExtruderHmi::fbParamHandle::FileCreationDate |
Parameters_Settings_StoreCountValue_Textblock | PLC1.Extruder.fbCoExtruderHmi::fbParamHandle::FileStoreCount |
Parameters_Settings_StoredDateValue_Textblock | PLC1.Extruder.fbCoExtruderHmi::fbParamHandle::FileStoreDate |
Parameters_Settings_Load_StateIndicator | PLC1.Extruder.fbCoExtruderHmi::fbParamHandle::LoadingStatus |
Parameters_Settings_Save_StateIndicator | PLC1.Extruder.fbCoExtruderHmi::fbParamHandle::SavingStatus |
Contents/Navigation/Parameters/Parameters_Blowpin.content
Control ID | PLC Symbol |
|---|---|
Parameters_Settings_Load_Button | PLC1.Blowpin.fbBlowpinHmi::fbParamHandle::Load |
Parameters_Settings_Save_Button | PLC1.Blowpin.fbBlowpinHmi::fbParamHandle::Save |
Parameters_Settings_CreationDateValue_Textblock | PLC1.Blowpin.fbBlowpinHmi::fbParamHandle::FileCreationDate |
Parameters_Settings_StoreCountValue_Textblock | PLC1.Blowpin.fbBlowpinHmi::fbParamHandle::FileStoreCount |
Parameters_Settings_StoredDateValue_Textblock | PLC1.Blowpin.fbBlowpinHmi::fbParamHandle::FileStoreDate |
Parameters_Settings_Load_StateIndicator | PLC1.Blowpin.fbBlowpinHmi::fbParamHandle::LoadingStatus |
Parameters_Settings_Save_StateIndicator | PLC1.Blowpin.fbBlowpinHmi::fbParamHandle::SavingStatus |
Contents/Navigation/Parameters/Parameters_Carriage.content
Control ID | PLC Symbol |
|---|---|
Parameters_Settings_Load_Button | PLC1.Carriage.fbCarriageHmi::fbParamHandle::Load |
Parameters_Settings_Save_Button | PLC1.Carriage.fbCarriageHmi::fbParamHandle::Save |
Parameters_Settings_CreationDateValue_Textblock | PLC1.Carriage.fbCarriageHmi::fbParamHandle::FileCreationDate |
Parameters_Settings_StoreCountValue_Textblock | PLC1.Carriage.fbCarriageHmi::fbParamHandle::FileStoreCount |
Parameters_Settings_StoredDateValue_Textblock | PLC1.Carriage.fbCarriageHmi::fbParamHandle::FileStoreDate |
Parameters_Settings_Load_StateIndicator | PLC1.Carriage.fbCarriageHmi::fbParamHandle::LoadingStatus |
Parameters_Settings_Save_StateIndicator | PLC1.Carriage.fbCarriageHmi::fbParamHandle::SavingStatus |
Contents/Navigation/Parameters/Parameters_Clamp.content
Control ID | PLC Symbol |
|---|---|
Parameters_Settings_Load_Button | PLC1.Clamp.fbClampHmi::fbParamHandle::Load |
Parameters_Settings_Save_Button | PLC1.Clamp.fbClampHmi::fbParamHandle::Save |
Parameters_Settings_CreationDateValue_Textblock | PLC1.Clamp.fbClampHmi::fbParamHandle::FileCreationDate |
Parameters_Settings_StoreCountValue_Textblock | PLC1.Clamp.fbClampHmi::fbParamHandle::FileStoreCount |
Parameters_Settings_StoredDateValue_Textblock | PLC1.Clamp.fbClampHmi::fbParamHandle::FileStoreDate |
Parameters_Settings_Load_StateIndicator | PLC1.Clamp.fbClampHmi::fbParamHandle::LoadingStatus |
Parameters_Settings_Save_StateIndicator | PLC1.Clamp.fbClampHmi::fbParamHandle::SavingStatus |
Contents/Navigation/Parameters/Parameters_Wtc.content
Control ID | PLC Symbol |
|---|---|
Parameters_Settings_Load_Button | PLC1.Wtc.fbWtcHmi::fbParamHandle::Load |
Parameters_Settings_Save_Button | PLC1.Wtc.fbWtcHmi::fbParamHandle::Save |
Parameters_Settings_CreationDateValue_Textblock | PLC1.Wtc.fbWtcHmi::fbParamHandle::FileCreationDate |
Parameters_Settings_StoreCountValue_Textblock | PLC1.Wtc.fbWtcHmi::fbParamHandle::FileStoreCount |
Parameters_Settings_StoredDateValue_Textblock | PLC1.Wtc.fbWtcHmi::fbParamHandle::FileStoreDate |
Parameters_Settings_Load_StateIndicator | PLC1.Wtc.fbWtcHmi::fbParamHandle::LoadingStatus |
Parameters_Settings_Save_StateIndicator | PLC1.Wtc.fbWtcHmi::fbParamHandle::SavingStatus |
Contents/Navigation/Parameters/Parameters_Monitoring.content
Control ID | PLC Symbol |
|---|---|
Parameters_Settings_Load_Button | PLC1.Monitoring::fbParamHandle::Load |
Parameters_Settings_Save_Button | PLC1.Monitoring::fbParamHandle::Save |
Parameters_Settings_CreationDateValue_Textblock | PLC1.Monitoring::fbParamHandle::FileCreationDate |
Parameters_Settings_StoreCountValue_Textblock | PLC1.Monitoring::fbParamHandle::FileStoreCount |
Parameters_Settings_StoredDateValue_Textblock | PLC1.Monitoring::fbParamHandle::FileStoreDate |
Parameters_Settings_Load_StateIndicator | PLC1.Monitoring::fbParamHandle::LoadingStatus |
Parameters_Settings_Save_StateIndicator | PLC1.Monitoring::fbParamHandle::SavingStatus |
Contents/Navigation/Parameters/Parameters_Setpoints.content
Control ID | PLC Symbol |
|---|---|
Parameters_Settings_Load_Button | PLC1.Setpoints::fbParamHandle::Load |
Parameters_Settings_Save_Button | PLC1.Setpoints::fbParamHandle::Save |
Parameters_Settings_CreationDateValue_Textblock | PLC1.Setpoints::fbParamHandle::FileCreationDate |
Parameters_Settings_StoreCountValue_Textblock | PLC1.Setpoints::fbParamHandle::FileStoreCount |
Parameters_Settings_StoredDateValue_Textblock | PLC1.Setpoints::fbParamHandle::FileStoreDate |
Parameters_Settings_Load_StateIndicator | PLC1.Setpoints::fbParamHandle::LoadingStatus |
Parameters_Settings_Save_StateIndicator | PLC1.Setpoints::fbParamHandle::SavingStatus |
Parameter
Name | Type | Description |
|---|---|---|
- | - | - |
Return value
Type | Description |
|---|---|
void | no return value |
NuGet package: Beckhoff.TwinCAT.HMI.Plastic.Functions
Available from version 12.6.0
Usage: TC3 Plastic Application HMI projects