E_TcPfw_TerminalType

This enumeration defines identifiers for the supported types of I/O terminals. These identifiers are used in ST_TcPfw_TempMparamFromHmi_Itf.

Syntax

TYPE E_TcPfw_TerminalType:
(* last modification: 16.03.2009 *)
(
eTcPfwTermT_NoSensor,

eTcPfwTermT_KL_RangeLow:=1000,
eTcPfwTermT_KL300x, (* +/-10V *)
eTcPfwTermT_KL301x, (* 0..20mA *)
eTcPfwTermT_KL302x, (* 4..20mA *)
eTcPfwTermT_KL304x, (* 0..20mA *)
eTcPfwTermT_KL305x, (* 4..20mA *)
eTcPfwTermT_KL306x, (* 0..10V *)
eTcPfwTermT_KL310x, (* +/-10V *)
eTcPfwTermT_KL311x, (* 0..20mA *)
eTcPfwTermT_KL312x, (* 4..20mA *)
eTcPfwTermT_KL313x, (* +/-10V *)
eTcPfwTermT_KL314x, (* 0..20mA *)
eTcPfwTermT_KL315x, (* 4..20mA *)
eTcPfwTermT_KL317x, (* 0..2V *)
eTcPfwTermT_KL318x, (* +/-2V *)
eTcPfwTermT_KL340x, (* +/-10V *)
eTcPfwTermT_KL344x, (* 0..20mA *)
eTcPfwTermT_KL346x, (* 0..10V *)
eTcPfwTermT_KL331x, (* thermo couple *)
eTcPfwTermT_KL_RangeHigh,

eTcPfwTermT_EL_RangeLow:=2000,
eTcPfwTermT_EL331x, (* thermo couple *)
eTcPfwTermT_EL320x, (* PT100/PT1000 *)
eTcPfwTermT_EL316x, (* 0..10V *)
eTcPfwTermT_EL_RangeHigh,

eTcPfwTermT_XX_RangeLow:=3000,
eTcPfwTermT_FM33xx, (* thermo couple *)
eTcPfwTermT_EM8908, (* multi signal backplane *)
eTcPfwTermT_XX_RangeHigh,

eTcPfwTermT_Customized:=10000
);
END_TYPE

Values

Name

Description

eTcPfwTermT_NoSensor

No I/O electronics available, the zone is operated in simulation.

eTcPfwTermT_KL_RangeLow

Lower limit of identifiers for K-bus terminals.

eTcPfwTermT_KL300x

K-bus terminals for connection of 1 or 2 ±10 V signals.

eTcPfwTermT_KL301x

K-bus terminals for connection of 1 or 2 0..20 mA signals.

eTcPfwTermT_KL302x

K-bus terminals for connection of 1 or 2 4..20 mA signals.

eTcPfwTermT_KL304x

K-bus terminals for connection of 1, 2 or 4 0..20 mA signals.

eTcPfwTermT_KL305x

K-bus terminals for connection of 1, 2 or 4 4..20 mA signals.

eTcPfwTermT_KL306x

K-bus terminals for the connection of 1, 2 or 4 0..10 V signals.

eTcPfwTermT_KL310x

K-bus terminals for connection of 2 ±10 V signals.

eTcPfwTermT_KL311x

K-bus terminals for connection of 2 0..20 mA signals.

eTcPfwTermT_KL312x

K-bus terminals for connection of 2 4..20 mA signals.

eTcPfwTermT_KL313x

K-bus terminals for connection of 2 ±10 V signals.

eTcPfwTermT_KL314x

K-bus terminals for connection of 2 0..20 mA signals.

eTcPfwTermT_KL315x

K-bus terminals for connection of 2 4..20 mA signals.

eTcPfwTermT_KL317x

K-bus terminals for the connection of 2 0..2 V signals.

eTcPfwTermT_KL318x

K-bus terminals for connection of 2 ±2 V signals.

eTcPfwTermT_KL340x

K-bus terminals for connection of 4 or 8 ±10 V signals.

eTcPfwTermT_KL344x

K-bus terminals for connection of 4 or 8 0..20 mA signals.

eTcPfwTermT_KL346x

K-bus terminals for the connection of 4 or 8 0..10 V signals.

eTcPfwTermT_KL331x

K-bus terminals for direct connection of 1, 2 or 4 thermocouples.

eTcPfwTermT_KL_RangeHigh

Upper limit of identifiers for K-bus terminals.

eTcPfwTermT_EL_RangeLow

Lower limit of identifiers for EtherCAT Terminals.

eTcPfwTermT_EL331x

EtherCAT Terminals for direct connection of 1, 2 or 4 thermocouples.

eTcPfwTermT_EL320x

EtherCAT Terminals for direct connection of PT100 or PT1000 sensors.

eTcPfwTermT_EL316x

EtherCAT Terminals for the connection of analog inputs.

eTcPfwTermT_EL_RangeHigh

Upper limit of identifiers for EtherCAT Terminals.

eTcPfwTermT_XX_RangeLow

Lower limit of identifiers for other modules.

eTcPfwTermT_FM33xx

Profibus module for direct connection of 12 or 32 thermocouples. Note: An adjustment function block must be called.

eTcPfwTermT_EM8908

I/O board for injection molding machines.

eTcPfwTermT_XX_RangeHigh

Upper limit of identifiers for other modules.

eTcPfwTermT_Customized

The temperature input is supplied by the application.