ETcVnPolarizedImageInterpolation

Offers interpolation options for polarized image demosaicing.

Syntax

Definition:

TYPE ETcVnPolarizedImageInterpolation :
(
    TCVN_PII_NONE             := -1,
    TCVN_PII_NEAREST_NEIGHBOR := 0,
    TCVN_PII_BILINEAR         := 1,
    TCVN_PII_BICUBIC          := 2,
    TCVN_PII_LANCZOS4         := 4
)DINT;
END_TYPE

Values

Name

Description

TCVN_PII_NONE

No interpolation, i.e. demosaicing returns images with half width and height.

TCVN_PII_NEAREST_NEIGHBOR

Images are scaled to full resolution using nearest neighbor interpolation.

TCVN_PII_BILINEAR

Images are scaled to full resolution using bilinear interpolation.

TCVN_PII_BICUBIC

Images are scaled to full resolution using bicubic interpolation.

TCVN_PII_LANCZOS4

Images are scaled to full resolution using Lanczos4 interpolation.