ETcVnCameraState
Specifies the state of a camera controller, which controls an attached camera.
Syntax
Definition:
enum ETcVnCameraState : LONG
{
CS_ERROR = -1,
CS_INITIAL = 0,
CS_INITIALIZING = 1,
CS_INITIALIZED = 2,
CS_OPENING = 3,
CS_OPENED = 4,
CS_STARTACQUISITION = 5,
CS_ACQUIRING = 6,
CS_STOPACQUISITION = 7,
CS_RESETTINGFEATURES = 8,
CS_TRIGGERING = 9,
CS_CLOSING = 10
};Values
|
Name |
Description |
|---|---|
|
CS_ERROR |
The camera controller is in an error state (e.g. the connection to the camera was lost). |
|
CS_INITIAL |
The camera controller is in the initial state and ready to establish the connection to the camera. |
|
CS_INITIALIZING |
The camera controller is initializing the camera. |
|
CS_INITIALIZED |
The camera controller has initialized the camera. |
|
CS_OPENING |
The camera controller is establishing the connection to the camera. |
|
CS_OPENED |
The connection to the camera has been established and the camera controller is ready to start the image acquisition. |
|
CS_STARTACQUISITION |
The camera controller is starting the image acquisition. |
|
CS_ACQUIRING |
The camera is sending images (either streaming or manually triggered, depending on the configuration). |
|
CS_STOPACQUISITION |
The camera controller is stopping the image acquisition. |
|
CS_RESETTINGFEATURES |
The camera controller is resetting the features on the camera. |
|
CS_TRIGGERING |
The camera controller is processing a softwaretrigger. |
|
CS_CLOSING |
The camera controller is closing the connection to the camera. |