RespSetChargingProfile

With this method, an OCPP client responds to a Set Charging Profile request from the corresponding OCPP server.

Syntax
METHOD RespSetChargingProfile : BOOL
VAR_INPUT
hMessageId : T_OCPP_MessageId;
eStatus : E_OCPP1_ChargingProfileStatus;
END_VAR
Return value
Name | Type | Description |
|---|---|---|
RespSetChargingProfile | BOOL | The method returns the return value TRUE if the call was successful. A method call is also considered successfully completed in the event of an error. |
Inputs
Name | Type | Description |
|---|---|---|
hMessageId | MessageId of the received message. | |
eStatus | Response whether the Charge Point was able to implement the requested Charging Profile. |
Possible errors are output at the outputs bError and hrErrorCode of the function block instance.