RespLocalList

RespLocalList 1:

With this method, an OCPP client responds to a Send Local List request from the corresponding OCPP server.

RespLocalList 2:

Syntax

METHOD RespLocalList : BOOL
VAR_INPUT
    hMessageId : T_OCPP_MessageId;
    eStatus    : E_OCPP1_UpdateStatus;
END_VAR

RespLocalList 3: Return value

Name

Type

Description

RespLocalList

BOOL

The method returns the return value TRUE if the call was successful. A method call is also considered successfully completed in the event of an error.

RespLocalList 4: Inputs

Name

Type

Description

hMessageId

T_OCPP_MessageId

MessageId of the received message.

eStatus

E_OCPP1_UpdateStatus

Response whether the Charge Point was able to receive the sent Local Authorization List and perform the update.

Possible errors are output at the outputs bError and hrErrorCode of the function block instance.