RespClearChargingProfile

RespClearChargingProfile 1:

With this method, an OCPP client responds to a Clear Charging Profile request from the corresponding OCPP server.

RespClearChargingProfile 2:

Syntax

METHOD RespClearChargingProfile : BOOL
VAR_INPUT
    hMessageId : T_OCPP_MessageId;
    eStatus    :  E_OCPP1_ClearChargingProfileStatus;
END_VAR

RespClearChargingProfile 3: Return value

Name

Type

Description

RespClearChargingProfile

BOOL

The method returns the return value TRUE if the call was successful. A method call is also considered successfully completed in the event of an error.

RespClearChargingProfile 4: Inputs

Name

Type

Description

hMessageId

T_OCPP_MessageId

MessageId of the received message.

eStatus

E_OCPP1_ClearChargingProfileStatus

Response whether the Charge Point was able to implement the requested clearing.

Possible errors are output at the outputs bError and hrErrorCode of the function block instance.