RecvChangeConfiguration

With this method, an OCPP client receives a Change Configuration request from the corresponding OCPP server. To respond to the request, the method RespChangeConfiguration must be called.

Syntax
METHOD RecvChangeConfiguration : BOOL
VAR_OUTPUT
hMessageId : T_OCPP_MessageId;
sKey : T_OCPP1_ConfigKey;
sValue : T_OCPP1_ConfigValue;
END_VAR
Return value
Name | Type | Description |
|---|---|---|
RecvChangeConfiguration | BOOL | The method returns the return value TRUE if the call was successful. A method call is also considered successfully completed in the event of an error. |
Outputs
Name | Type | Description |
|---|---|---|
hMessageId | MessageId of the received message. | |
sKey | Name of the Configuration Key to be changed. | |
eType | New value for the Configuration Key. |
Possible errors are output at the outputs bError and hrErrorCode of the function block instance.