RespDiagnosticsStatusNotification

RespDiagnosticsStatusNotification 1:

With this method, an OCPP server responds to a Status Notification from the connected OCPP client.

RespDiagnosticsStatusNotification 2:

Syntax

METHOD RespDiagnosticsStatusNotification : BOOL
VAR_INPUT
    hMessageId : T_OCPP_MessageId;
END_VAR

RespDiagnosticsStatusNotification 3: Return value

Name

Type

Description

RespDiagnosticsStatusNotification

BOOL

The method returns the return value TRUE if the call was successful. A method call is also considered successfully completed in the event of an error.

RespDiagnosticsStatusNotification 4: Inputs

Name

Type

Description

hMessageId

T_OCPP_MessageId

MessageId of the received message.

Possible errors are output at the outputs bError and hrErrorCode of the function block instance.