SendGetLocalListVersion
With this method, an OCPP server sends a Get Local List Version request to the corresponding OCPP client. The response from the OCPP client is processed directly within the method.
Syntax
METHOD SendGetLocalListVersion : BOOL
VAR_INPUT
hStationId : UDINT;
END_VAR
VAR_OUTPUT
nListVersion : UDINT;
END_VAR
Return value
Name | Type | Description |
---|---|---|
SendGetLocalListVersion | BOOL | The method returns the return value TRUE if the call was successful. A method call is also considered successfully completed in the event of an error. |
Inputs
Name | Type | Description |
---|---|---|
hStationId | UDINT | Identifier of the OCPP client in the instance of the OCPP server. |
Outputs
Name | Type | Description |
---|---|---|
nListVersion | UDINT | Contains the version number of the Local Authorization List currently available in the Charge Point. |
Possible errors are output at the outputs bError and hrErrorCode of the function block instance.