RecvFirmwareStatusNotification

With this method, an OCPP server receives a Firmware Status Notification from an OCPP client. To respond to the Firmware Status Notification, the method RespFirmwareStatusNotification must be called.

Syntax
METHOD RecvFirmwareStatusNotification : BOOL
VAR_INPUT
hStationId : UDINT;
END_VAR
VAR_OUTPUT
hMessageId : T_OCPP_MessageId;
eStatus : E_OCPP1_FirmwareStatus;
END_VAR
Return value
Name | Type | Description |
|---|---|---|
RecvFirmwareStatusNotification | BOOL | The method returns the return value TRUE if the call was successful. A method call is also considered successfully completed in the event of an error. |
Inputs
Name | Type | Description |
|---|---|---|
hStationId | UDINT | Identifier of the OCPP client in the instance of the OCPP server. |
Outputs
Name | Type | Description |
|---|---|---|
hMessageId | MessageId of the received message. | |
eStatus | Status of a firmware installation. |
Possible errors are output at the outputs bError and hrErrorCode of the function block instance.