RespReset

RespReset 1:

With this method, an OCPP client responds to a Reset request from the corresponding OCPP server.

RespReset 2:

Syntax

METHOD RespReset : BOOL
VAR_INPUT
    hMessageId : T_OCPP_MessageId;
    eStatus    : E_OCPP1_ResetStatus;
END_VAR

RespReset 3: Return value

Name

Type

Description

RespReset

BOOL

The method returns the return value TRUE if the call was successful. A method call is also considered successfully completed in the event of an error.

RespReset 4: Inputs

Name

Type

Description

hMessageId

T_OCPP_MessageId

MessageId of the received message.

eStatus

E_OCPP1_ResetStatus

The status shows whether the Charge Point was able to accept the Reset request.

Possible errors are output at the outputs bError and hrErrorCode of the function block instance.