RespRemoteStopTransaction

RespRemoteStopTransaction 1:

With this method, an OCPP client responds to a Remote Stop Transaction request from the corresponding OCPP server.

RespRemoteStopTransaction 2:

Syntax

METHOD RespRemoteStopTransaction : BOOL
VAR_INPUT
    hMessageId : T_OCPP_MessageId;
    eStatus    : E_OCPP1_RemoteStartStopStatus;
END_VAR

RespRemoteStopTransaction 3: Return value

Name

Type

Description

RespRemoteStopTransaction

BOOL

The method returns the return value TRUE if the call was successful. A method call is also considered successfully completed in the event of an error.

RespRemoteStopTransaction 4: Inputs

Name

Type

Description

hMessageId

T_OCPP_MessageId

MessageId of the received message.

eStatus

E_OCPP1_RemoteStartStopStatus

The status indicates whether the Charge Point has accepted the request to stop a transaction.

Possible errors are output at the outputs bError and hrErrorCode of the function block instance.