InsertAttribute

This method adds an attribute to an XML node. The attribute can be placed at a specific position. The XML node and the position and name of the new attribute are transferred to the method as input parameters. The method returns a reference to the newly added attribute. A value for the attribute can then be entered using the SetAttribute() method, for example.
Syntax
METHOD InsertAttribute : SXmlAttribute
VAR_INPUT
n : SXmlNode;
before : SXmlAttribute;
END_VAR
VAR_IN_OUT CONSTANT
name : STRING;
END_VAR
Return value
Name | Type |
|---|---|
InsertAttribute | SXmlAttribute |
Inputs
Name | Type |
|---|---|
n | SXmlNode |
before | SXmlAttribute |
/
Inputs/Outputs
Name | Type |
|---|---|
name | STRING |
Sample call:
xmlNewAttr := fbXml.InsertAttribute(xmlNode, xmlBeforeAttr, 'SomeName');