SendCustomMessageTypes

SendCustomMessageTypes 1:

This method is called once to overwrite the standard categories (Default, Info, Warning, Error, Critical). Categories can be overwritten again by calling them up again. The user-defined categories can then also be used in the SendMessageEx method.

Syntax

METHOD SendCustomMessageTypes : BOOL
VAR_INPUT
    aCustomTypes : ARRAY[1..5] OF STRING;
END_VAR

SendCustomMessageTypes 2: Return value

Name

Type

Description

SendCustomMessageTypes

BOOL

The method returns the return value TRUE if the call was successful.

SendCustomMessageTypes 3: Inputs

Name

Type

Description

aCustomTypes

ARRAY[1…5] OF STRING

User-defined categories of (push) messages. Exactly five categories must be entered in the desired order.

Possible errors are output at the outputs bError and hrErrorCode of the function block instance.