Configuration of the push agent

The push agent is currently available on Windows and can be installed via TcPkg (see Installation). The installation saves a configuration file under the following path:

C:\ProgramData\Beckhoff\TwinCAT\Functions\TF6735-IoT-Communicator\TcIotPushAgent.conf

In this configuration file, the connection between push agent and message broker can be configured. In addition, the creation of a log file can also be activated.

Configuration of the push agent 1:

Settings within the file

Setting

Default

Values

Description

LOGFILE

False

False/True

Activation of a log file. Is saved under C:\Program Data\Beckhoff\TwinCAT\Functions\TF6735-IotCommunicator.

MIN_SEVERITY

0

0-4

0: All messages are sent as push messages.
1: Information, Warning, Error and Critical are sent.
2: Warning, Error and Critical.
3: Error and Critical.
4: Critical.

When using custom categories, the order from 0 to 4 is decisive. If a non-existent category is specified, the messages are also sent as push messages.

HOST

127.0.0.1

-

IP address or host name of the MQTT broker to which the push agent should connect.

PORT

1883

-

Port number of the broker, usually 1883 or 8883 for MQTT communication.

TOPIC

test

-

Main topic via which the messages from the associated PLC program are communicated.

USE_USR_PWD_AUTHENTICATION

False

True/False

True if authentication with user name and password is to be used.

USERNAME

-

-

User name for the connection to the Message Broker.

PASSWORD

-

-

Password for the connection to the message broker

USE_TLS_ENCRYPTION

False

True/False

True if TLS encryption is to be used.

TLSVERSION

-

tlsv1, tlsv1.1, tlsv1.2, tlsv1.3

TLS version used.

CAFILE

-

-

Path to the CA certificate

PFXFILE

-

-

Path to the client certificate (PFX).

PFXPASSWORD

-

-

Password for the PFX file.

ALLOWUNTRUSTED

-

True/False

This setting disables the validation of the server certificate.