Use Microsoft Azure IoT Hub Device Twin
The following section describes step-by-step how to use the configurator to set up a connection to Microsoft Azure IoT Hub and the Microsoft Azure IoT Hub Device Twin service.
Configure ADS gate, channel and symbols
Follow the step-by-step instructions to create an ADS gate and a subscriber channel and add symbols to the channel’s configuration.
- The topology view is activated.
- 1. Right-click the canvas and select Add Gate (ADS).
- 2. Select the new gate and configure ADS specific settings in the properties window (AmsNetId, AdsPort, …).
- 3. Right-click the new gate and select Add Channel (Subscriber).
- 4. Select the new channel and set “SamplingMode” to “Cyclic”. Leave all other fields on their default settings.
- 5. Open the Target Browser.
- 6. Navigate to the ADS device and add some symbols to the configuration by dragging them to the subscriber channel.
- An ADS gate and a subscriber channel have been created. Symbols have been added to the channel.
![]() | AMS Net ID Make sure that the AMS Net ID, which has been configured on the ADS gate, matches the ADS device that you selected with the target browser. |
Configure Azure IoT Hub gate and Device Twin channel
Follow the step-by-step instructions to create an Azure IoT Hub gate and channels for telemetry data and the Device Twin.
- The topology view is activated
- 1. Right-click the canvas and select Add Gate (IoT Hub).
- 2. Select the new gate and configure IoT Hub related settings in the properties window (device name, primary key, CA certificate).
- 3. Right-click the new gate and select Add Channel (Publisher).
- 4. Select the new channel and set "SamplingMode" to "OnChange", "Formatter" to "Simple JSON" and "Name" to "Telemetry Data" (optional). Leave all other fields on their default settings.
- 5. Right-click the new gate and select Add Channel (Device Twin Publisher).
- 6. Select the new channel and set "SamplingMode" to "OnChange", "Formatter" to "Simple JSON" and "Name" to "Device Twin" (optional). Leave all other fields on their default settings.
- 7. Right-click the new gate and select Add Channel (Device Twin Subscriber).
- 8. Select the new channel and set "SamplingMode" to "OnChange", "Formatter" to "Simple JSON" and "Name" to "Device Twin GET" (optional). Leave all other fields on their default settings.
- You have configured an Azure IoT Hub connection and three channels - one for telemetry data and two for the Device Twin. In the step you have to decide which source symbols from the ADS gate will be treated as telemetry data and which symbols should be send to the Device Twin via the Device Twin Publisher channel. The Device Twin Subscriber channel can be used to retrieve updates to the Device Twin from cloud-based backenend applications (so-called "desired" updates). Every property expected has to be added as a symbol to that channel, using the property name as symbol name and URN.
Create mapping
Follow the step-by-step instructions to create a mapping between source and destination symbols. Note that a mapping can only be created between channels that have different roles (e.g. between a subscriber and a publisher channel and vice versa).
Drag-and-drop - Channel:
While holding the CTRL key, drag the subscriber channel to the publisher channel.
The configurator automatically creates new symbols on the publisher channel and a mapping between the source and destination symbol.
Drag-and-drop – Symbol:
While holding the CTRL key, drag a symbol from the subscriber channel to either an existing symbol on the publisher channel or to the publisher channel itself.
The configurator creates a link between source and destination symbol or, if the symbol has been dragged to a channel object, creates the destination symbol automatically
Activate configuration
Follow the step-by-step instructions to activate the currently opened configuration.
- 1. Select the target system via the toolbar.
- 2. Click the Activate Configuration button.
- A dialog opens asking if you want to switch the target TC3 IoT Data Agent into run mode.
- 3. Confirm the dialog with Yes if you want to switch the mode. Otherwise, choose No.
- The configuration is activated.
The resulting configuration may look like this: