FB_IotFunctions_Connector

The function block enables communication with a local/remote TC3 IoT Data Agent installation. The Execute method of the function block must be called cyclically in order to ensure the background communication with the TC3 IoT Data Agent to facilitate the reception of messages. All connection parameters and global settings are available as input parameters.
Syntax
FUNCTION_BLOCK FB_IotFunctions_Connector
VAR_INPUT
sAmsNetId : STRING;
nDefaultRequestTimeout : UDINT;
nDefaultMessageRetryInterval : UDINT;
nDefaultMessageCumulativeTimeout : UDINT;
END_VAR
VAR_OUTPUT
hrInitializationErrorCode : HRESULT;
hrLastMessageErrorCode : HRESULT;
driverOTCID : OTCID;
pStIotFunctionsRequests : POINTER TO ST_IotFunctionsRequestContainer;
END_VAR
Inputs
Designation | Type | Description |
|---|---|---|
sAmsNetId | STRING | Target Data Agent Instance AmsNetId [127.0.0.1.1.1] |
nDefaultRequestTimeout | UDINT | Default timeout value in milliseconds [10000] |
nDefaultMessageRetryInterval | UDINT | Default message retry interval in milliseconds (0 disables retries) [0] |
nDefaultMessageCumulativeTimeout | UDINT | Default cumulative timeout in milliseconds (if message data is successfully received, the timeout of the relevant request is extended by this value) [0] |
Outputs
Designation | Type | Description |
|---|---|---|
hrInitializationErrorCode | HRESULT | HRESULT of driver instantiation and configuration |
hrLastMessageErrorCode | HRESULT | HRESULT of latest reported error occurred in any message during the Execute call. |
driverOTCID | OTCID | OTCID of the instantiated driver (can be passed on to FB input variables for requests and messages in environments with multiple data agents) |
pStIotFunctionsRequests | POINTER TO ST_IotFunctionsRequestContainer | Description of latest error code. |
Methods
Designation | Description |
|---|---|
Enables background communication with TC3 IoT Data Agent. The method must be called cyclically. |
Requirements
Development environment | Target platform | PLC libraries to include |
|---|---|---|
TwinCAT v3.1.4022.14 | IPC or CX (c86, x64, ARM) | Tc3_IotFunctions |