Param_Acsi
Namespace: Tc3_Acsi
Type: Parameter list
Library: Tc3_Acsi (Tc3_Acsi.compiled-library)
Parameter
Name | Type | Value | Description |
|---|---|---|---|
cMaxLengthOfObjectName | UDINT | 64 | Maximum length of the object name string. |
cMaxLengthOfObjectReference | UDINT | 255 | Maximum length of the reference string. |
cMaxLengthOfVisString64 | UDINT | 64 | Maximum length of the “VisString64” data type. |
cMaxLengthOfVisString129 | UDINT | 129 | Maximum length of the “VisString129” data type. |
cMaxLengthOfVisString255 | UDINT | 255 | Maximum length of the “VisString255” data type. |
cMaxLengthOfClassName | UDINT | 20 | Maximum name length of the logical node or CDC. |
cMaxLengthOfQualityString | INT(18..19) | 18 | Maximum length of the “Quality” data type formatted as a string. When the value is 19, the optional parameter “Derived” is also included in the string. |
|
|
|
|
cDefault_TimeStamp | T_UtcTime | secondSinceEpoch:=DT#1970-01-01-00:00:00, fractionOfSecond:=[0,0,0], quality:=(LeapSecondsKnown:=0, ClockFailure:=0, ClockNotSynchronized:=0, Accuracy0:=0, Accuracy1:=0, Accuracy2:=0, Accuracy3:=0, Accuracy4:=0) | Default initial value for all “TimeStamp” DA instances. |
cDefault_EntryTime_D | DATE | D#1984-01-01 | Default initial value for all "EntryTime.day" data element instances. |
cDefault_EntryTime_TimeOfDay | TOD | TOD#0:0:0 | Default initial value for all “EntryTime.TimeOfDay” data element instances. |
cDefault_EntryTime | T_BinaryTime | timeOfDay:=cDefault_EntryTime_TimeOfDay, day:=0 | Default initial value for all “EntryTime” DA instances. |
cDefault_Currency | STRING(3) | '' | Default initial value for all “Currency” DA instances. |
cDefault_EntryID | T_OCTET8 | [8(0)] | Default initial value for all “EntryID” DA instances. |
cDefault_Originator | ST_AcsiOriginator | orCat:=E_AcsiOrCategory.NotSupported, orIdent:=[64(0)] | Default initial value for all “Originator” DA instances. |
cDefault_Quality | ST_AcsiQuality | Validity0:=0, Validity1:=0, Overflow:=0, OutOfRange:=0, BadReference:=0, Oscillatory:=0, Failure:=0, OldData:=0, Inconsistent:=0, Inaccurate:=0, Source:=0, Test:=0, OperatorBlocked:=0 | Default initial value for all “Quality” DA instances. |
cDefault_Dbpos | E_AcsiDbpos | E_AcsiDbpos.Intermediate | Default initial value for all “Dbpos” DA instances. |
cDefault_Tcmd | E_AcsiTcmd | E_AcsiTcmd.Stop | Default initial value for all “Tcmd” DA instances. |
cDefault_BrCB_OptFlds | ST_AcsiOptionalFields | SequenceNumber:=TRUE, ReportTimeStamp:=TRUE, ReasonForInclusion:=TRUE, DataSetName:=TRUE, DataReference:=FALSE, BufferOverflow:=TRUE, EntryID:=TRUE, ConfRevision:=TRUE, Segmentation:=FALSE | Default initial value for all BRCB “OptionalFields” DA instances. |
cDefault_BrCB_TrgOps | ST_AcsiTriggerConditions | DataChange:=FALSE, QualityChange:=FALSE, DataUpdate:=FALSE, Integrity:=FALSE, GeneralInterrogation:=TRUE | Default initial value for all BRCB “TriggerConditions” DA instances. |
cDefault_BrCB_TimeOfEntry | T_BinaryTime | timeOfDay:=TOD#0:0:0, day:=0 | Default initial value for all BRCB “TimeOfEntry” DA instances. |
cDefault_UrCB_OptFlds | ST_AcsiOptionalFields | SequenceNumber:=TRUE, ReportTimeStamp:=TRUE, ReasonForInclusion:=TRUE, DataSetName:=TRUE, DataReference:=FALSE, BufferOverflow:=FALSE, EntryID:=FALSE, ConfRevision:=TRUE, Segmentation:=FALSE | Default initial value for all URCB “OptionFields” DA instances. |
cDefault_UrCB_TrgOps | ST_AcsiTriggerConditions | DataChange:=FALSE, QualityChange:=FALSE, DataUpdate:=FALSE, Integrity:=FALSE, GeneralInterrogation:=TRUE | Default initial value for all URCB “TriggerConditions” DA instances. |
cDefault_GoCB_MinTime | UDINT(1..16#7FFFFFFF) | 50 | Default GOCB delay time for sending the repetitions in milliseconds. |
cDefault_GoCB_MaxTime | UDINT(1..16#7FFFFFFF) | 5,000 | Default GOCB monitoring time in milliseconds. |
cDefault_GoCB_Multiplier | BYTE(1..BYTE#16#FF) | 2 | Default initial value for GOOSE publisher transmission repeat multiplier. |
cDefault_GoCB_Security | DWORD(0..16#0FFFFFFF) | 0 | Default GOOSE header Reserved1 and Reserved2 28 security bits. |
cDefault_LCB_OldEntrTm | T_BinaryTime | timeOfDay:=TOD#0:0:0, day:=0 | Default initial value for all LCB “OldEntrTm”. |
cDefault_LCB_NewEntrTm | T_BinaryTime | timeOfDay:=TOD#0:0:0, day:=0 | Default initial value for all LCB “NewEntrTm”. |
cDefault_LCB_OptFlds | ST_AcsiLogOptionalFields | ReasonForInclusion:=TRUE | Default initial value for all LCB “OptionFields” DA instances. |
cDefault_LCB_TrgOps | ST_AcsiTriggerConditions | DataChange:=FALSE, QualityChange:=FALSE, DataUpdate:=FALSE, Integrity:=FALSE, GeneralInterrogation:=TRUE | Default initial value for all LCB “TriggerConditions” DA instances. |
cDefault_MsvCB_OptFlds | ST_AcsiSvOptionalFields | SampleSynchronized:=TRUE | Default initial value for all MSVCB “OptionFields” DA instances. |
cDefault_UsvCB_OptFlds | ST_AcsiSvOptionalFields | SampleSynchronized:=TRUE | Default initial value for all USVCB “OptionFields” DA instances. |
cDefault_Per | E_AcsiPer | E_AcsiPer.Hourly | Default initial value for all “perRs” or “chrPerRs” DA instances. |
cDefault_Acs | E_AcsiAcs | E_AcsiAcs.Low | Default initial value for all “sptAcs” DA instances. |
|
|
|
|
cPresence_AnalogueValue | E_AcsiAnalogueValuePresCond | E_AcsiAnalogueValuePresCond.both_CO_f | Default presence of the “AnalogueValue” data elements: “i” and/or “f”. In the status value “i” and “f” (both) are visible, in the control value only “f” is visible. |
cPresence_Cell_xEnd | BOOL | FALSE | Default presence of “Cell.xEnd”. |
cPresence_Cell_yStart | BOOL | FALSE | Default presence of “Cell.yStart”. |
cPresence_Cell_yEnd | BOOL | FALSE | Default presence of “Cell.xEnd”. |
cPresence_Point_zVal | BOOL | FALSE | Default presence of “Point.zVal”. |
cPresence_RangeConfig_limDb | BOOL | FALSE | Default presence of “RangeConfig.limDb”. |
cPresence_Unit_multiplier | BOOL | FALSE | Default presence of “Unit.multiplier”. |
cPresence_ValWithTrans_transInd | BOOL | FALSE | Default presence of “ValWithTrans.transInd”. |
cPresence_Vector_ang | BOOL | FALSE | Default presence of “Vector.ang”. |
cPresence_Oper_AnalogueValue_operTm | BOOL | FALSE | Default presence of “Oper.ctlVal(AnalogueValue).operTm” |
cPresence_Oper_BOOLEAN_operTm | BOOL | FALSE | Default presence of “Oper.ctlVal(BOOLEAN).operTm” |
cPresence_Oper_CODEDENUM_operTm | BOOL | FALSE | Default presence of “Oper.ctlVal(CODEDENUM).operTm” |
cPresence_Oper_ENUMERATED_operTm | BOOL | FALSE | Default presence of “Oper.ctlVal(ENUMERATED).operTm” |
cPresence_Oper_INT32_operTm | BOOL | FALSE | Default presence of “Oper.ctlVal(INT32).operTm” |
cPresence_Oper_INT8_operTm | BOOL | FALSE | Default presence of “Oper.ctlVal(INT8).operTm” |
cPresence_SBOw_AnalogueValue_operTm | BOOL | FALSE | Default presence of “SBOw.ctlVal(AnalogueValue).operTm” |
cPresence_SBOw_BOOLEAN_operTm | BOOL | FALSE | Default presence of “SBOw.ctlVal(BOOLEAN).operTm” |
cPresence_SBOw_CODEDENUM_operTm | BOOL | FALSE | Default presence of “SBOw.ctlVal(CODEDENUM).operTm” |
cPresence_SBOw_ENUMERATED_operTm | BOOL | FALSE | Default presence of “SBOw.ctlVal(ENUMERATED).operTm” |
cPresence_SBOw_INT32_operTm | BOOL | FALSE | Default presence of “SBOw.ctlVal(INT32).operTm” |
cPresence_SBOw_INT8_operTm | BOOL | FALSE | Default presence of “SBOw.ctlVal(INT8).operTm” |
cPresence_Cancel_AnalogueValue_operTm | BOOL | FALSE | Default presence of “Cancel.ctlVal(AnalogueValue).operTm” |
cPresence_Cancel_BOOLEAN_operTm | BOOL | FALSE | Default presence of “Cancel.ctlVal(BOOLEAN).operTm” |
cPresence_Cancel_CODEDENUM_operTm | BOOL | FALSE | Default presence of “Cancel.ctlVal(CODEDENUM).operTm” |
cPresence_Cancel_ENUMERATED_operTm | BOOL | FALSE | Default presence of “Cancel.ctlVal(ENUMERATED).operTm” |
cPresence_Cancel_INT32_operTm | BOOL | FALSE | Default presence of “Cancel.ctlVal(INT32).operTm” |
cPresence_Cancel_INT8_operTm | BOOL | FALSE | Default presence of “Cancel.ctlVal(INT8).operTm” |
cPresence_BrCB_ResvTms | BOOL | FALSE | Default presence of “BRCB.ResvTms” |
cPresence_BrCB_Owner | BOOL | FALSE | Default presence of “BRCB.Owner” |
cPresence_UrCB_Owner | BOOL | FALSE | Default presence of “URCB.Owner” |
cPresence_LCB_OptFlds | BOOL | FALSE | Default presence of “LCB.OptFlds” |
cPresence_LCB_BufTm | BOOL | FALSE | Default presence of “LCB.BufTm” |
cPresence_GoCB_MinTime | BOOL | FALSE | Default presence of “GOCB.MinTime” |
cPresence_GoCB_MaxTime | BOOL | FALSE | Default presence of “GOCB.MaxTime” |
cPresence_GoCB_FixedOffs | BOOL | FALSE | Default presence of “GOCB.FixedOffs” |