WriteBySymbol
This method reads the value of a specified ADS symbol and saves it in the standard table structure specified by Beckhoff. ADS symbols from other ADS devices can also be read.
Syntax
METHOD WriteBySymbol : BOOL
VAR_INPUT
hDBID: UDINT;
sTableName: T_MaxString;
stADSDevice: ST_ADSDevice;
stSymbol: ST_Symbol;
eDBWriteMode: E_WriteMode := E_WriteMode.eADS_TO_DB_Append;
nRingBuffParameter: UDINT;
END_VAR
Inputs
Name | Type | Description |
|---|---|---|
hDBID | UDINT | Indicates the ID of the database to be used. |
sTableName | T_MaxString | Name of the table that is to be read. |
stADSDevice | ST_ADSDevice | ADS device from which a symbol is to be logged in the standard table structure. |
stSymbol | ST_Symbol | Symbol name of the variable to be written |
eDBWriteMode | E_WriteMode | Indicates the write mode. (append, update, ring buffer) |
nRingBuffParameter | UDINT | Additional parameter(s) for the "ring buffer" write mode |
Return value
Name | Type | Description |
|---|---|---|
WriteBySymbol | BOOL | Displays the status of the method. Returns TRUE as soon as the method execution is finished, even in the event of an error. |
Sample
This sample shows how to use the FB_PLCDBWriteEvt.WriteBySymbol method:
VAR
fbPLCDBWrite : FB_PLCDBWriteEvt(sNetID := '', tTimeout := T#5S);
myValue : LREAL := 43.23;
myAdsDevice : ST_ADSDevice;
mySymbol : ST_Symbol;
tcMessage : I_TcMessage;
END_VAR// Set ADSDevice Information
myAdsDevice.sDevNetID := '127.0.0.1.1.1';
myAdsDevice.nDevPort := 851;
myAdsDevice.eADSRdWrtMode := E_ADSRdWrtMode.bySymbolName;
myAdsDevice.tTimeout := T#5S;
// Set Symbol Information
mySymbol.eDataType := E_PLCDataType.eType_LREAL;
mySymbol.sDBSymbolName := 'MySymbol';
mySymbol.sSymbolName := 'MAIN.myValue';
mySymbol.nBitSize := 8;
// Call Functionblock
IF fbPLCDBWrite.WriteBySymbol(
hDBID:= 1,
sTableName:= 'myTable_WithLReal',
stADSDevice:= myAdsDevice,
stSymbol:= mySymbol,
eDBWriteMode:= E_WriteMode.eADS_TO_DB_Append,
nRingBuffParameter:= 1)
THEN
IF fbPLCDBWrite.bError THEN
tcMessage := fbPLCDBWrite.ipTcResult;
nState := 255;
ELSE
nState := 0;
END_IF
END_IFResult in the database:
ID | Timestamp | Name | Value |
|---|---|---|---|
28 | '2018-01-30 14:04:19' | 'MyValue' | 41.23 |
29 | '2018-01-30 14:04:29' | 'MyValue' | 42.23 |
30 | '2018-01-30 14:04:39' | 'MyValue' | 43.23 |
31 | '2018-01-30 14:06:12’ | ‘MySymbol’ | 86.2 |