FB_DBReloadConfig

FB_DBReloadConfig 1:

The XML configuration file can be reloaded using the FB_DBReloadConfig function block.
If changes have been made to the XML configuration file, the changes must be made known to the Database Server using FB_DBReloadConfig.

VAR_INPUT

VAR_INPUT
    sNetID   : T_AmsNetId;
    bExecute : BOOL;
    tTimeout : TIME;
END_VAR

sNetID: String containing the AMS network ID of the target device, at which the ADS command is directed.

bExecute: The command is executed with a rising edge.

tTimeout: States the length of the timeout that may not be exceeded by execution of the ADS command.

VAR_OUTPUT

VAR_OUTPUT
    bBusy  : BOOL;
    bError : BOOL;
    nErrID : UDINT;
END_VAR

bBusy: The command is in the process of being transmitted by ADS. No new command will be accepted as long as bBusy remains TRUE.

bError: Becomes TRUE, as soon as an error occurs.

nErrID: Returns the ADS error code if the bError output is set.

Requirements

Development environment

Target platform

PLC libraries to be linked

TwinCAT v3.0.0

PC or CX (x86)

Tc2_Database