FB_TlsSocketConnect

FB_TlsSocketConnect 1:

The FB_TlsSocketConnect function block enables a client to establish a new TCP/IP connection to a remote server via the TwinCAT TCP/IP Connection Server, secured via TLS. If successful, a new socket is opened, and the associated connection handle is returned at the hSocket output. The connection handle is required by the function blocks FB_SocketSend and FB_SocketReceive, for example, in order to exchange data with a remote server. If a connection is no longer required, it can be closed with the function block FB_SocketClose. Several clients can establish a connection with the remote server at the same time. For each new client, a new socket is opened and a new connection handle is returned. The TwinCAT TCP/IP Connection Server automatically assigns a new IP port number for each client. The TLS parameters can be defined via the function blocks FB_TlsSocketAddCa, FB_TlsSocketAddCrl, FB_TlsSocketSetPsk and FB_TlsSocketSetCert. Programming samples for their use can be found in our samples.

FB_TlsSocketConnect 2: Inputs

VAR_INPUT
    sSrvNetId   : T_AmsNetId:='';
    sRemoteHost : STRING(TCPADS_TLS_HOSTNAME_SIZE):='';
    nRemotePort : UDINT:=0;
    flags       : ST_TlsConnectFlags:=DEFAULT_TLSCONNECTFLAGS;
    bExecute    : BOOL;
    tTimeout    : TIME:=T#45s;(*!!!*)
END_VAR

Name

Type

Description

sSrvNetId

T_AmsNetId

String containing the network address of the TwinCAT TCP/IP Connection Server. For the local computer, ‘127.0.0.1’ can also be specified.

sRemoteHost

STRING(TCPADS_TLS_HOSTNAME_SIZE)

IP address (Ipv4) of the remote server in the form of a string (e.g. 172.33.5.1). An empty string can be entered on the local computer for a server.

nRemotePort

UDINT

IP port number of the remote server (e.g. 200).

flags

ST_TlsConnectFlags

Additional (optional) client connection parameters.

bExecute

BOOL

The function block is enabled by a positive edge at this input.

tTimeout

TIME 

Maximum time allowed for the execution of the function block.

FB_TlsSocketConnect 3:

Setting the maximum execution time of the function block

Do not set the value "tTimeout" too low, as timeout periods of > 30 s can occur in case of a network interruption. If the value is too low, command execution would be interrupted prematurely, and ADS error code 1861 (timeout elapsed) would be returned instead of the Winsocket error WSAETIMEDOUT.

FB_TlsSocketConnect 4: Inputs/outputs

VAR_IN_OUT
    hSocket : T_HSOCKET;
END_VAR

Name

Type

Description

hSocket

T_HSOCKET

TCP/IP connection handle to the newly opened local client socket

FB_TlsSocketConnect 5: Outputs

VAR_OUTPUT
    bBusy  : BOOL;
    bError : BOOL;
    nErrId : UDINT;
END_VAR

Name

Type

Description

bBusy

BOOL

This output is active if the function block is activated. It remains active until acknowledgement.

bError

BOOL

If an error occurs during the transfer of the command, then this output is set once the bBusy output was reset.

nErrId

UDINT

If an bError output is set, this parameter returns the TwinCAT TCP/IP Connection Server error number.

Requirements

Development environment

Target platform

PLC libraries to be integrated (category group)

TF6310 v3.3.15.0 or later

TwinCAT v3.1.0

PC or CX (x86, x64, Arm®)

Tc2_TcpIp (Communication)