FB_FTP_FileRename

FB_FTP_FileRename 1:

Files on an FTP server can be renamed with the function block FB_FTP_FileRename. This function block uses an already open connection to an FTP server.

FB_FTP_FileRename 2: Inputs

VAR_INPUT
sNetID      : T_AmsNetId := '';
hFTP        : T_HFTP;
sOLDFilename: T_MaxString:= '';
sNEWFilename: T_MaxString:= '';
bExecute    : BOOL;
tTimeout    : TIME       := T#15s;
END_VAR

Name

Type

Description

sNetID

T_AmsNetId

A string containing the AMS network ID of the target device, at which the ADS command is directed.

hFTP

T_HFTP

Handle of the FTP server.

sOLDFilename

T_MaxString

The old filename of the file to be changed.

sNEWFilename

T_MaxString

The new filename.

bExecute

BOOL

The function block is executed with the rising edge.

tTimeout

TIME

Indicates the timeout period.

FB_FTP_FileRename 3: Outputs

VAR_OUTPUT
bBusy : BOOL;
bError: BOOL;
nErrID: UDINT;
END_VAR

Name

Type

Description

bBusy

BOOL

The command is in the process of being transmitted by ADS. No new command will be accepted as long as "bBusy" remains TRUE.

bError

BOOL

Becomes TRUE, as soon as an error occurs.

nErrID

UDINT

Returns the corresponding error code in the event of a set bError output.

Requirements

Development Environment

Target Platform

PLC Libraries to include

TwinCAT v3.0 Build 3102

PC or CX (x86)

Tc2_FTP