FB_FTP_DirRemove

Directories can be deleted from the FTP server with the function block FB_FTP_DirRemove. This function block uses an already open connection to an FTP server.
Inputs
VAR_INPUT
sNetID : T_AmsNetId := '';
hFTP : T_HFTP;
sDirectory: T_MaxString:= '';
bExecute : BOOL;
tTimeout : TIME := T#15s;
END_VARsNetID : Is a string containing the AMS network ID of the target device to which the ADS command is directed.
hFTP : Handle of the FTP server.
sDirectory : The name of the directory to be deleted.
bExecute : The function block is executed with the rising edge.
tTimeout : Specifies the timeout period.
Outputs
VAR_OUTPUT
bBusy : BOOL;
bError : BOOL;
nErrID : UDINT;
END_VAR
bBusy : Command is being transmitted via ADS. No new command will be accepted as long as "bBusy" remains TRUE.
bError: Becomes TRUE, as soon as an error occurs.
nErrID : Returns the associated error code in the event of a set bError output.
Requirements
|
Development Environment |
Target Platform |
PLC Libraries to include |
|---|---|---|
|
TwinCAT v3.0 Build 3102 |
PC or CX (x86) |
Tc2_FTP |