FB_FTP_Open

With the function block FB_FTP_Open a connection to an FTP server can be established. The handle returned can then be used to perform further actions on the FTP server. The connection type used is Passive FTP.
Inputs
VAR_INPUT
sNetID : T_AmsNetId:= '';
sHost : T_IPv4Addr:= '127.0.0.1';
nPort : UDINT := 21;
sUsername: STRING := '';
sPassword: STRING := '';
bExecute : BOOL;
tTimeout : TIME := T#15s;
END_VAR
Name | Type | Description |
|---|---|---|
sNetID | T_AmsNetId | A string containing the AMS network ID of the target device, at which the ADS command is directed. |
sHost | T_IPv4Addr | A string containing the IPv4 address of the FTP server. |
nPort | UDINT | FTP Port (default 21) |
sUsername | STRING | User name for FTP server authentication |
sPassword | STRING | Password for FTP server authentication |
bExecute | BOOL | The function block is executed with the rising edge. |
tTimeout | TIME | Indicates the timeout period. |
Outputs
VAR_OUTPUT
bBusy : BOOL;
bError : BOOL;
nErrID : UDINT;
hFTP : T_HFTP;
END_VAR
Name | Type | Description |
|---|---|---|
bBusy | BOOL | The command is in the process of being transmitted by ADS. No new command will be accepted as long as "bBusy" remains TRUE. |
bError | BOOL | Becomes TRUE, as soon as an error occurs. |
nErrID | UDINT | Returns the corresponding error code in the event of a set bError output. |
hFTP | T_HFTP | Handle of the FTP connection |
Requirements
|
Development Environment |
Target Platform |
PLC Libraries to include |
|---|---|---|
|
TwinCAT v3.0 Build 3102 |
PC or CX (x86) |
Tc2_FTP |