UA_GetNamespaceIndex

This function block collects the namespace index for a namespace URI. The namespace index is required for identifying symbols, for example, if the function blocks UA_Read or UA_Write are used.
Inputs
VAR_INPUT
Execute : BOOL;
ConnectionHdl : DWORD;
NamespaceUri : STRING(MAX_STRING_LENGTH);
Timeout : TIME := DEFAULT_ADS_TIMEOUT;
END_VARName | Type | Description |
|---|---|---|
Execute | BOOL | The command is triggered by a rising edge at this input. |
ConnectionHdl | DWORD | Connection handle previously output by the function block UA_Connect. |
NamespaceUri | STRING | Namespace URI to be resolved. For the TwinCAT OPC UA Server, this is "urn:BeckhoffAutomation:Ua:PLC1“" for the first PLC runtime. |
Timeout | TIME | Time until the function is aborted. DEFAULT_ADS_TIMEOUT is a global constant, set to 5 seconds. |
Outputs
VAR_OUTPUT
NamespaceIndex : UINT;
Done : BOOL;
Busy : BOOL;
Error : BOOL;
ErrorID : DWORD;
END_VAR Name | Type | Description |
|---|---|---|
NamespaceIndex | UINT | Namespace Index of the given namespace URI. This can be used in other function blocks, e.g. UA_NodeGetHandle or UA_MethodGetHandle. |
Done | BOOL | Switches to TRUE if the function block was executed successfully. |
Busy | BOOL | TRUE until the function block has executed a command, at the most for the duration of the "Timeout" at the input. The inputs accept no new command as long as Busy = TRUE. It is not the connection time that is monitored but the reception time. |
Error | BOOL | Switches to TRUE if an error occurs while executing a command. The command-specific error code is included in ErrorID. |
ErrorID | DWORD | Contains the command-specific error code of the most recently executed command. |
Requirements
Development environment | Target platform | PLC libraries to include |
|---|---|---|
TwinCAT 3.1 | Win32, Win64, CE-X86, CE-Arm® | Tc3_PLCopen_OpcUa |