Method – parameter (Init)

Parameter

Group

Return Type

Input Type

Explanation

Init

General

BOOL

BOOL

Initialization

GetObjectName

General

STRING(20)

–

Returns the name of this TcCOM object.

GetCCoodinateModuloTolerance

General

LREAL

–

Returns the modulo tolerance of the C-axis.

GetCCoodinateModulus

General

LREAL

–

Returns the modulus for the C-axis.

GetMoverHeight

General

LREAL

–

Returns the height of the mover.

GetMoverWidth

General

LREAL

–

Returns the width of the mover.

GetInitialPosition

Simulation

MoverVector

–

Returns the mover's starting position.

GetSimulationMode

Simulation

BOOL

–

Returns the simulation mode of the mover.

GetMaximalAcceleration

Maximum Dynamics

MoverVector

–

Returns the maximum acceleration of the mover.

GetMaximalDeceleration

Maximum Dynamics

MoverVector

–

Returns the maximum deceleration of the mover.

GetMaximalVelocity

Maximum Dynamics

MoverVector

–

Returns the maximum velocity of the mover.

GetMaximalJerk

Maximum Dynamics

MoverVector

–

Returns the maximum jerk of the mover.

GetMaximumDynamicA

Maximum Dynamics

DynamicLimits1D

–

Returns the maximum dynamics for the A-axis.

GetMaximumDynamicB

Maximum Dynamics

DynamicLimits1D

–

Returns the maximum dynamics for the B-axis.

GetMaximumDynamicC

Maximum Dynamics

DynamicLimits1D

–

Returns the maximum dynamics for the C-axis.

GetMaximumDynamicXY

Maximum Dynamics

DynamicLimits1D

–

Returns the maximum dynamics for the X-axis and Y-axis.

GetMaximumDynamicZ

Maximum Dynamics

DynamicLimits1D

–

Returns the maximum dynamics for the Z-axis.

GetDefaultAcceleration

Default Dynamics

MoverVector

–

Returns the default acceleration of the mover.

GetDefaultDeceleration

Default Dynamics

MoverVector

–

Returns the default deceleration of the mover.

GetDefaultVelocity

Default Dynamics

MoverVector

–

Returns the default velocity of the mover.

GetDefaultJerk

Default Dynamics

MoverVector

–

Returns the default jerk of the mover.

GetDefaultDynamicA

Default Dynamics

DynamicLimits1D

–

Returns the default dynamics for the A-axis.

GetDefaultDynamicB

Default Dynamics

DynamicLimits1D

–

Returns the default dynamics for the B-axis.

GetDefaultDynamicC

Default Dynamics

DynamicLimits1D

–

Returns the default dynamics for the C-axis.

GetDefaultDynamicXY

Default Dynamics

DynamicLimits1D

–

Returns the default dynamics for the X-axis and Y-axis.

GetDefaultDynamicZ

Default Dynamics

DynamicLimits1D

–

Returns the default dynamics for the Z-axis.

GetMaximumLagFilterTime

Monitoring

MoverVector

–

Returns the maximum lag filter time.

GetMaximumPositionLagValue

Monitoring

MoverVector

–

Returns the maximum value of the position lag.

GetPositionLagMonitoringEnabled

Monitoring

BOOL

–

Returns the activated monitoring of the position lag.