Method – parameter (Init)

Parameter

Group

Return Type

Input Type

Explanation

Init

–

BOOL

BOOL

Initialization

GetObjectName

–

STRING(20)

–

Returns the name of this TcCOM object.

GetMoverParametrizationSetId

General

OTCID

–

Returns the Parameter Set that is configured for this mover.

SetMoverParametrizationSetOid

General

BOOL

OTCID

Sets a new Parameter Set object ID for this mover.

GetPayloadInertia

Payload

ST_TcIoPayload

–

Returns the payload inertia of this mover.

GetPayloadPro­ductsOfInertia

Payload

ST_TcIoPayloadProductsOfInertia

–

Returns the inertia products of the payload of this mover.

SetPayloadInertia

Payload

BOOL

ST_TcIoPayload

Sets the payload inertia of this mover.

SetPayloadPro­ductsOfInertia

Payload

BOOL

ST_TcIoPayloadProductsOfInertia

Sets the inertia products of the payload of this mover.

GetForceLimitMax

Force Limits

REFERENCE TO Force6D

–

Returns the maximum force limit of this mover.

GetForceLimitMin

Force Limits

REFERENCE TO Force6D

–

Returns the minimum force limit of this mover.

SetForceLimitMax

Force Limits

BOOL

Force6D

Sets the maximum force limit for this mover.

SetForceLimitMin

Force Limits

BOOL

Force6D

Sets the minimum force limit for this mover.

GetControllersOn

Controller

ST_TcIoControllersOn

–

Returns the status of the controller of this mover.

SetControllersOn

Controller

BOOL

ST_TcIoControllersOn

Sets the status of the controller for this mover.

GetPositionOffset

PositionOffset

MoverVector

–

Returns the current position offset of this mover.

SetPositionOffset

PositionOffset

BOOL

MoverVector

Sets a position offset for this mover.