Method - parameter (Init)

Parameter

Group

Return Type

Input Type

Explanation

Init

–

BOOL

BOOL

Initialization

GetObjectName

–

STRING(20)

–

Returns the name of this TcCOM object.

GetIpMcMover

–

I_McPlanarMover

–

Returns the interface of the linked NC mover object.

GetAccessoryId

General

MoverAccessoryID

–

Returns the configured accessory ID of this mover.

GetAccessoryIdCount

General

UDINT

–

Returns the number of configured accessory IDs that are configured for this mover.

GetBTN

General

STRING(13)

–

Returns the BTN of this mover.

GetMoverType

General

XPlanarMoverType

–

Returns the mover type.

GetMoverParametrizationSetId

General

OTCID

–

Returns the Parameter Set that is configured for this mover.

GetTaskOid

General

OTCID

–

Returns the task object ID of this mover.

SetMoverParametrizationSetOid

General

BOOL

OTCID

Sets a new Parameter Set object ID for this mover.

SetTaskOid

General

BOOL

OTCID

Sets a new task object ID for this mover.

GetPayloadInertia

Payload

ST_TcIoPayload

–

Returns the payload inertia of this mover.

GetPayloadPro­ductsOfInertia

Payload

ST_TcIoPayloadProductsOfInertia

–

Returns the inertia products of the payload of this mover.

SetPayloadInertia

Payload

BOOL

ST_TcIoPayload

Sets the payload inertia of this mover.

SetPayloadPro­ductsOfInertia

Payload

BOOL

ST_TcIoPayloadProductsOfInertia

Sets the inertia products of the payload of this mover.

GetSimulationModeStartPosition

SimulationMode

REFERENCE TO SimulationModeStartPosition

–

Returns the start position of the mover in simulation mode.

GetForceLimitMax

ForceLimits

REFERENCE TO Force6D

–

Returns the maximum force limit of this mover.

GetForceLimitMin

ForceLimits

REFERENCE TO Force6D

–

Returns the minimum force limit of this mover.

SetForceLimitMax

ForceLimits

BOOL

Force6D

Sets the maximum force limit for this mover.

SetForceLimitMin

ForceLimits

BOOL

Force6D

Sets the minimum force limit for this mover.

GetControllersOn

Controller

ST_TcIoControllersOn

–

Returns the status of the controller of this mover.

SetControllersOn

Controller

BOOL

ST_TcIoControllersOn

Sets the status of the controller for this mover.

SetMovementArea

Methods

BOOL

EnterOrLeaveMovementAreaParameters

Sets the MovementArea parameters of this mover.

SetMoverCommunicationCommand

Communication

BOOL

MoverCommunicationCommand

Sets the mover communication command for this mover.

GetPositionOffset

Position Offset

MoverVector

–

Returns the current position offset of this mover.

SetPositionOffset

Position Offset

BOOL

MoverVector

Sets a position offset for this mover.