MC_WriteParameter

MC_WriteParameter 1:

This function block writes a numeric (LREAL) parameter value to the axis.
The command is typically processed synchronously.

Syntax

Definition:

FUNCTION_BLOCK MC_WriteParameter
VAR_INPUT
    Axis        : Type_PtpReadWriteParameter;
    Execute     : BOOL;
    ParameterId : EAxisParameterId;
    Value       : LREAL;
END_VAR
VAR_OUTPUT
    Done        : BOOL;
    Busy        : BOOL;
    Error       : BOOL;
    ErrorId     : UDINT;
END_VAR

MC_WriteParameter 2: Inputs

Name

Type

Description

Axis

Type_PtpReadWriteParameter

Reference to the axis

Execute

BOOL

Trigger the command with rising edge.

ParameterId

EAxisParameterId

Identifier of the parameter to write.

Value

LREAL

Value of the parameter to write.

MC_WriteParameter 3: Outputs

Name

Type

Description

Done

BOOL

Parameter value has been successfully written.

Busy

BOOL

Function block is not finished.

Error

BOOL

Error occurred within function block.

ErrorId

UDINT

Error identifier

Version information

  • TwinCAT Standard >= v3.1.4026.23.1
  • TF5500 MC3 Base >= v4.0.6